125TC/OEL HIGH CONTAINMENT

Categories ,
This new compact OEL High-Containment sampling device allows the removal of a product sampled under contained conditions.

The OEL (Occupational Exposure Limit) describes the maximum concentration of a drug substance which can be tolerated in the air of the production room without any negative effect to the health of the operators.
  • (OEL) level range : 1-10μg / m3 (without aspiration)
  • (OEL) level range : below 1μg / m3 (with aspiration)

MODEL

125TC/OEL

NOMINAL SIZE

DN 50 (2’’)

PRESSURE CLASS

PN6

PRESSURE DESIGN

Vacuum to 6 bar (0-87 psi).                        Max pressure of active valve: 6 bar when connected to passive / opened 0.2 bar.  Max pressure passive valve: 0.2 bar once disconnected from active

MAX TEMPERATURE

+180°C / +356°F

MIN. TEMPERATURE

-20°C / -4°F

BODY MATERIAL

Stainless steel (1.4435/04/316L), Hastelloy® (2.4602/C22)

SEALS MATERIAL

EPDM, FKM, FFKM, PEEK (All FDA)

INT. ROUGHNESS

Ra ≤0.8 µm (polishing on request)

EXT. ROUGHNESS

Ra ≤3.2 µm (polishing on request)

SAMPLE UNIT

Bottle 150 ml*, glass Borosilicate with stainless steel protection (*autre sur demande)

HIGH CONTAINMENT VALVE

Split butterfly valve, consisting of 2 separable half-valves, with locking system: 1x active module isolating the outlet of sampling valve & 1x passive module, removable in closed position, isolating the sampling bottle.

WEIGHT/GEWICHT/POIDS

18kg / 40 LBS

APPLICABLE STANDARDS

2014/68/UE (PED) – 2014/34/UE (ATEX) – FDA